Icom 7300 always switching to wrong filter...

3 posts / 0 new
Last post
on5hb
on5hb's picture
Icom 7300 always switching to wrong filter...

Hi Petr, I have a request. I have checked the commands that are being send to the Icom 7300, you send the mode with a filter/bandwith
But this makes the Icom 7300 use LSB/USB but always with Filter3, but that is a DX very small filter.
I normally use filter 1.
You send something like M USB 2200 as rigctrl command, but I like to send M USB 2700 as default.
Is there a way you let me choose and bandwidth setting instead of your default so I can choose the filter I want to have.
I know this is different for all sets, but I want to be able to set a number, if not it uses your setting.
Ergo if I tell it to be 2700Hz it will send via rigctrl: M LSB 2700
Making my set pick filter 1 and not 3.
I use the DX-cluster option a lot, but it changes my filter all the time, as such I want to be able to set my own number.

Thanks if you make this adjustable.

ok1rr
ok1rr's picture
Re: Icom 7300 always switching to wrong filter...

Hi there, try File->Preferences->Modes and adjust BW of your preferences.

73,
Martin, OK1RR

on5hb
on5hb's picture
Thanks Martin, I feel stupid

Thanks Martin, I feel stupid now, forgot about that setting....it works!

Greetings, Bas. ON5HB